| Genera l features | Unit | iglidur® K | test method | 
| Density | g/cm³ | 1,52 | |
| Colour | yellow-beige | ||
| Max. humidity absorption at 23°C/50% R. H. | % weight | 0,1 | DIN 53495 | 
| Max. water absorption | % weight | 0,6 | |
| Coefficient of surface friction, dynamic, against steel | µ | 0,06 - 0,21 | |
| pv values (dry) | MPa x m/s | 0,30 | |
| Mechanical properties | |||
| Bending E-module | MPa | 3.500 | DIN 53457 | 
| Tensile strength at +20 °C | MPa | 80 | DIN 53452 | 
| compressive strength | MPa | 60 | |
| Maximum recommended surface pressure (20° C) | MPa | 50 | |
| Shore D-hardness | 72 | DIN 53505 | |
| Physical and thermal properties | |||
| Max. long term application temperature | °C | +170 | |
| Max. short term application temperature | °C | +240 | |
| Minimum application temperature | °C | -40 | |
| thermal / heat conductivity | W/m x K | 0,25 | ASTM C 177 | 
| Coefficient of thermal expansion (at 23° C) | K-1 x 10-5 | 3 | DIN 53752 | 
| Electrical properties | |||
| Specific forward resistance | Ωcm | > 1012 | DIN IEC 93 | 
| surface resistance | Ω | > 1012 | DIN 53482 | 
 
         
         
        | m/s | Rotary | oscillating | Linear | 
| Constant | 1 | 0,7 | 3 | 
| Short-term | 2 | 1,4 | 4 | 
| iglidur® K | Application temperature | 
| Lower | -40°C | 
| Upper, long-term | +170 °C | 
| Upper, short-term | +240 °C | 
| Secure axially in addition | +70 °C | 
| iglidur® K | Dry | Grease | Oil | Water | 
| Coefficients of friction µ | 0,06-0,21 | 0,09 | 0,04 | 0,04 | 
 
         
         
         
        | Medium | Resistance | 
| Alcohols | + to 0 | 
| Hydrocarbons | + | 
| Fats, oils, without additives | + | 
| Fuels | + | 
| Diluted acids | 0 to - | 
| Strong acids | - | 
| Diluted bases | + | 
| Strong bases | 0 | 
| Specific forward resistance | > 1012 Ωcm | 
| Surface resistance | > 1012 Ω | 
| by +23 °C/50 % r. F. | 0,1 Wt.-% | 
| Max. water absorption | 0,6 Wt.-% | 
 
        | Diameter d1 [mm] | Shaft h9 [mm] | iglidur® K E10 [mm] | Housing H7 [mm] | 
| Up to 3 | 0 - 0,025 | +0,014 +0,054 | 0 +0,010 | 
| > 3 bis 6 | 0 - 0,030 | +0,020 +0,068 | 0 +0,012 | 
| > 6 to 10 | 0 - 0,043 | +0,025 +0,083 | 0 +0,015 | 
| > 10 to 18 | 0 - 0,043 | +0,032 +0,102 | 0 +0,018 | 
| > 18 to 30 | 0 - 0,052 | +0,040 +0,124 | 0 +0,021 | 
| > 30 to 50 | 0 - 0,062 | +0,050 +0,150 | 0 +0,025 | 
| > 50 to 80 | 0 - 0,074 | +0,060 +0,180 | 0 +0,030 | 
| > 80 to 120 | 0 - 0,087 | +0,072 +0,212 | 0 +0,035 | 
| > 120 bis 180 | 0 - 0,100 | +0,085 +0,245 | 0 +0,040 | 
Table 07: Important tolerances iaw. ISO 3547-1 after press-fitting